Solution for plasma cutting machine cannot cut through


Solution for plasma cutting machine cannot cut through

Client machine configuration:

FL2300A Control System; FL1621 Torch Height Control; Huayuan LGK-120IGBT Plasma Source.

Cutting thickness:5mm mild steel

  1. Troubleshooting

  1. Checking consumables, replace the damaged parts
  2. Whether the plate has rust, resulting in poor conductivity
  3. The air pressure is less than 0.5Mpa
  4. Use a multimeter to measure whether the plasma output voltage is stable during cutting

 

  1. If there is no problem with the above, let's check the machine setting
  1. Adjust the positioning height to 3 or 4mm, and the perforation delay to 0.

b. System parameter - plasma - piercing time is adjusted to 0.5.

c. Plasma power supply selection “sheet”